37
Regulator
The regulator is the heart of your LP gas system,
with internal moving parts. Its function is to re-
duce the high and varied pressure from the LP
container to safe and consistent low operating
pressure. The small, or inlet, is the first stage and
reduces container pressure to 10-13 pounds. The
second stage will reduce the 10-13 pound pressure
to an operating pressure of 11" W.C. (water
column) or 6.35 oz. of outlet pressure to the travel
trailer system. The second stage is adjustable and
will need to be adjusted for precise operation. We
suggest this normal maintenance procedure be
performed once per year. DO NOT make any
attempt to adjust regulator. Have only an autho-
rized and competent technician make any
adjustments.
WARNING:
LP gas regulators must always be installed with the diaphragm
vent facing downward. Regulators that are not in compartment have been
equipped with a protective cover. Make sure that the regulator vent faces
downward and that the cover is kept in place to minimize vent blockage which
could result in excessive gas pressure causing fire or explosion.
Be sure your LP gas regulator is protected from road spray. If water enters the vent in the
regulator, it may freeze the pressure controlling diaphragm in the open position so that
the container pressure is applied to the appliances – a hazardous condition. Be sure to
carefully read the instructions given by the manufacturer of the regulator.
Automatic Changeover Regulator
(STANDARD FOR KIWI TOO, OPTION FOR KIWI)
The automatic changeover regulator allows both gas bottles to be turned on simulta-
neously. The arrow on the regulator handle indicates which bottle is in service. When the
indicated bottle in service becomes empty, changeover is automatically accomplished to
commence drawing fuel from the other bottle. At this point, the plastic window will
display a red signal or flag to indicate the condition. The lever should then be flipped
over to indicate service on the other bottle. The first bottle which was depleted can then
be turned off, uncoupled and taken to be refilled without disturbing the RV gas supply.
After refilling, it can be removed and again turned to the “ON” position. When the other
bottle is depleted, the LP gas supply will again be automatically changed back to the first
bottle.
WARNING:
All pilot lights & appliances must be turned OFF during
refueling of motor fuel tanks and/or LP Gas containers.
Содержание Kiwi