36
4. Attach the inverted flare x 11” Type-1 pigtail hose to the regulator inlet and the right
hand swivel nut to the cylinder valve.
WARNING: The pigtail hose must be installed to avoid tension or pulling
stress at either end of the hose.
WARNING: Keep the pigtail hose away from sharp edges of the cylinder
collar, rigid corners, walls, doors or other compartment structures including
the cover.
NOTE: The regulator is typically installed with the inlet fittings at the same level as the
cylinder outlet valves. Due to bracket design, wing nut clearance or cover restrictions, the
regulator fittings may not be in perfect alignment with the cylinder valves. A variance of
two (2) inches above or below the line will permit the hoses to be properly installed.
Main Supply Hose
The main supply hose will be attached from regulator to brass manifold fitting in the
frame of the travel trailer. Swivel brass nut on the main hose will be your final
attachment. There are several things to remember each time the container is removed:
1. Check that ALL fittings are tight.
2. Ensure ALL connections are tested with leak solution.
3. Open main valve slowly to avoid fast rush of gas to excess flow valve causing gas
freeze up. Should you experience a gas “freeze-up,” close main valve and wait
fifteen minutes before trying again.
4. Listen carefully - a “hissing” sound longer than one second may indicate a gas leak.
Close valve and search for leak.
ALL GAS LINES HAVE BEEN CHECKED WITH AIR
PRESSURE. DEALERS ARE REQUIRED TO RECHECK AND
ADJUST PRESSURE BEFORE DELIVERY TO CUSTOMERS.
3/8" MPT x 1/2" Female
Flare Swivel