THe MICROSILK

®

 CONTROL BOX 

The MicroSilk

®

 unit and water level sensor must be 

plugged into the proper receptacles for correct operation 
of the system. See 

Figure 10

 for connections: (A) The 

power cord for the MicroSilk

®

 pump control box must be 

plugged into the proper GFCI dedicated circuit for the 
system (see note above). (C) The MicroSilk

®

 pump’s power 

cord will need to be plugged into the control box (B). Refer 
to the ELECTRICAL section of this manual for connecting 
the pump to the control box. (D) Two-pin terminal for 
installation of the water sensor  switch to the MicroSilk 
control box.

NOTe: This diagram (Figure 10) also applies to 50 Hz, 

240v equipment, controls, and power supply systems. 

except that the MicroSilk and blower junction box 

must be connected into one dedicated 240v, 20 Amp 

GFCI circuit.

Figure 10

CONTROL BOX CONNECTIONS (cont.)

SIGNATURe eDITION  

MICROSILK

®

-AIRMASSeUR

®  

Jason’s Signature Edition MicroSilk

®

-AirMasseur

®

 system 

is the most advanced bath manufactured by Jason 
International, Inc. and features the ultimate in luxury bathing 
for the leisure bath industry. The MicroSilk

®

 and blower 

control boxes must be properly connected for the bath to 
function correctly.

THe AIRMASSeUR

®

 CONTROL BOX

The blower and ozone sanitation unit, must be plugged 
into the proper receptacles for correct operation of the 
MicroSilk

®

- AirMasseur

®

 system. See 

Figure 11

 for 

connections: Pre-wired power cord from blower (I) and 
ozone unit (G) to the control box (H). 

THe MICROSILK

®

 CONTROL BOX

The MicroSilk

®

 unit, keypad, LED light and water level/ 

temperature sensor must be plugged into the proper 
receptacle for correct operation of the MicroSilk

®

AirMasseur

®

 system. 

See Figure 11

 for connections:  

(A) The junction box for the MicroSilk

®

/blower control 

boxes must be connected into a 240v, 20 amp GFCI 
dedicated circuit. (C) The MicroSilk

®

 pump’s power cord 

will need to be plugged into the control box (B). Refer to the 

eLeCTRICAL

 section of this manual for connecting the 

pump to the control box.  Eight-pin mini-DIN terminal for 
installation of MicroSilk

®

-AirMasseur

®

 keypad (F). Six-pin 

mini-DIN terminals for the water/temperature sensor (D), 
and LED light (E) to the MicroSilk

®

 control box. 

NOTe: This diagram (Figure 11) also applies to 50 Hz, 

240v pumps, controls, and power supply systems.

Figure 11

Содержание Forma MicroSilk-AirMasseur

Страница 1: ...ble for ensuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been avoided...

Страница 2: ...lower is required and should be designed to draw in indoor ambient air at a minimum of 72 F 22 C INSTALLATION INSTRUCTIONS 4 Install the drain and overflow assembly to the bath shell according to the...

Страница 3: ...ation Operation and Maintenance manual of the separately packaged MicroSilk hydrotherapy bath unit WARNING SYSTEM UNDER PRESSURE NEVER PERFORM MAINTENANCE WHILE SYSTEM IS RUNNING Figure 3 Figure 4 Not...

Страница 4: ...ed following E T L Guidelines During installation if remote mounting of the blower is desired or required the following procedures should be followed NOTE Do not remote mount the blower more than 15 f...

Страница 5: ...stallation is to be done by a Massachusetts licensed plumber 4 Standard Premier Edition MicroSilk AirMasseur Control Box 120v The MicroSilk generator unit may be shipped separate from the bath Follow...

Страница 6: ...and controls must be positioned horizontally and located to permit access for inspection and servicing If the MicroSilk generator unit is shipped separate from the bath the MicroSilk pump s power cord...

Страница 7: ...to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks 1 Before water testing...

Страница 8: ...ower cord will need to be plugged into the control box B Refer to the ELECTRICAL section of this manual for connecting the pump to the control box D Two pin terminal for installation of the water sens...

Страница 9: ...by Jason International Inc and features the ultimate in luxury bathing for the leisure bath industry The MicroSilk and blower control boxes must be properly connected for the bath to function correctl...

Страница 10: ...bath system The air bath system includes a variable speed 1 HP air blower with heater and three 3 massage modes Continuous Wave or Pulse The system also includes a Chromatherapy mood light Automatic O...

Страница 11: ...Operating The Signature Edition MicroSilk AirMasseur Touchpad section for details on activating this setting Filling and Draining Close the drain and fill the bath with water at least two 2 inches 50...

Страница 12: ...r Pressing the icon the first time starts the blower in the constant high speed mode Pressing the icon again begins the wave mode indicated by a slow flashing light Pressing the icon a third time will...

Страница 13: ...ring the purge idle period LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds to change modes The Light icon should remain li...

Страница 14: ...nsure a quick response on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment ALL WARRANTY REPA...

Страница 15: ...water a Venturi clogged b Float valve no operating a Refer to installer dealer b Refer to installer dealer Pump operates but water is not being pumped a Suction or discharge blocked b Suction air leak...

Страница 16: ...itself or before time elapses a Blower motor overheated and thermal protection device deactivated motor possibly low voltage b GFCI tripped a Check that blower has sufficient ventilation and that the...

Страница 17: ...stamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should...

Отзывы: