Jason International, Inc. •
501.771.4477
Page 6 of 17
Customer Service : 800.255.5766
Copyright © 2013 Jason International.
INSTALLATION INSTRUCTIONS (cont.)
Signature edition MicroSilk
®
-AirMasseur
®
Control
Box.
The MicroSilk
®
generator unit may be shipped
separate from the bath. Follow the instructions for the
MicroSilk
®
Pump Assembly Field Installation
in the
Installation
section of this owner’s manual (instructions
are also packaged with the MicroSilk
®
unit packaging).
The blower is prewired to the control box. The control
boxes have a 36" (91cm) cord with a junction box
connection. The MicroSilk
®
and blower control boxes
are mounted on a stand that is temporarily secured
to the packing board for shipping. These boxes must
remain on the control box bracket so that the two
boxes can communicate properly through their infrared
communication feature.
During installation, the control box bracket and controls
must be positioned horizontally and located to permit
access for inspection and servicing.
If the MicroSilk
®
generator unit is shipped separate from
the bath, the MicroSilk
®
pump’s power cord will need to be
plugged into the control box. Connect the pump’s male J+J
plug to the female J+J plug of the control box’s load line.
The MicroSilk
®
and blower junction box must be plugged
into a dedicated 240v 20A, 50 or 60 Hz, GFCI protected
circuit.
(See Figure 8A)
DANGeR: Do not alter the factory installed wiring.
All building materials and wiring should be routed
away from the equipment or other heat-producing
components of the unit.
Figure 8
Standard/Premier Edition
Figure 8A
Signature Edition
NOTe:
The load neutral terminal is not
used. There should be no connection
to the load neutral terminal on the GFCI
circuit breaker. The green wire (GND-
GReeN) is the equipment ground and
should be connected to the neutral
bus found in the main breaker box.
L2-WHITE WITH
RED MARK
L1-BLACK
GND-GREEN
FROM CONTROL
L2
240 V
L1
NO CONNECTION
(LOAD NEUTRAL)
BREAKER BOX
BREAKER BOX CONNECTIONS