INSTALLATION INSTRUCTIONS (cont.)

CLeANING

1.

  Remove all loose debris

. Construction plaster or 

excess grout can be removed with the use of a wood 
(edge) trowel.

2. 

Paint or tar stains

 may need to be removed with a 

cleaner, such as paint thinner, turpentine, or isopropyl 
alcohol (rubbing alcohol). Never allow the cleaner to 
soak against the acrylic surface for long periods of time. 

Always rinse the surface immediately following the 

use of cleaners.

3.  Follow the manufacturer’s instructions for safe use of 

cleaning products. If the surface becomes scratched 
or dulled, it may be restored by using a quality plastic 
polish, like Novus Plastic Polish No. 2 (available from 
the Jason Dealer). 

It is always preferable to protect 

the acrylic surface during installation to minimize 

cleanup and prevent surface damage.

WATeR TeSTING

Before finishing the installation, it is recommended that the 
bath be water tested and the plumbing tested for leaks. 

1.  

Before water testing the bath

, make sure any pump 

unions are hand tight. Do not over tighten or use a pipe 
wrench. This will damage the unions and cause leaking. 
If the unit leaks with the unions hand tight, then loosen 
the union(s) and check the O-ring seal to ensure it is 
properly seated.

2.  

Fill and operate the bath

. Close the drain and fill the 

bath with water to at least 10 inches [25 cm] below the 
bath deck. The inlet temperature should not exceed 
140°F (60°C) as this could damage the acrylic surface. 
Refer to the 

FILLING AND DRAINING

 section of this 

owner’s manual for more information. 
 

NeVeR RUN THe PUMP WITHOUT eNOUGH WATeR 

IN THe BATH TO COVeR THe JeTS.

3.  

Inspect the plumbing for leaks.

4.  

Turn the equipment Off and then drain the water

The bath unit and its plumbing are designed to drain 
after each use whether used as a hydrotherapy bath, 
soaking bath, or when taking a shower.

Содержание Forma MicroSilk-AirMasseur

Страница 1: ...ble for ensuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been avoided...

Страница 2: ...lower is required and should be designed to draw in indoor ambient air at a minimum of 72 F 22 C INSTALLATION INSTRUCTIONS 4 Install the drain and overflow assembly to the bath shell according to the...

Страница 3: ...ation Operation and Maintenance manual of the separately packaged MicroSilk hydrotherapy bath unit WARNING SYSTEM UNDER PRESSURE NEVER PERFORM MAINTENANCE WHILE SYSTEM IS RUNNING Figure 3 Figure 4 Not...

Страница 4: ...ed following E T L Guidelines During installation if remote mounting of the blower is desired or required the following procedures should be followed NOTE Do not remote mount the blower more than 15 f...

Страница 5: ...stallation is to be done by a Massachusetts licensed plumber 4 Standard Premier Edition MicroSilk AirMasseur Control Box 120v The MicroSilk generator unit may be shipped separate from the bath Follow...

Страница 6: ...and controls must be positioned horizontally and located to permit access for inspection and servicing If the MicroSilk generator unit is shipped separate from the bath the MicroSilk pump s power cord...

Страница 7: ...to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks 1 Before water testing...

Страница 8: ...ower cord will need to be plugged into the control box B Refer to the ELECTRICAL section of this manual for connecting the pump to the control box D Two pin terminal for installation of the water sens...

Страница 9: ...by Jason International Inc and features the ultimate in luxury bathing for the leisure bath industry The MicroSilk and blower control boxes must be properly connected for the bath to function correctl...

Страница 10: ...bath system The air bath system includes a variable speed 1 HP air blower with heater and three 3 massage modes Continuous Wave or Pulse The system also includes a Chromatherapy mood light Automatic O...

Страница 11: ...Operating The Signature Edition MicroSilk AirMasseur Touchpad section for details on activating this setting Filling and Draining Close the drain and fill the bath with water at least two 2 inches 50...

Страница 12: ...r Pressing the icon the first time starts the blower in the constant high speed mode Pressing the icon again begins the wave mode indicated by a slow flashing light Pressing the icon a third time will...

Страница 13: ...ring the purge idle period LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds to change modes The Light icon should remain li...

Страница 14: ...nsure a quick response on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment ALL WARRANTY REPA...

Страница 15: ...water a Venturi clogged b Float valve no operating a Refer to installer dealer b Refer to installer dealer Pump operates but water is not being pumped a Suction or discharge blocked b Suction air leak...

Страница 16: ...itself or before time elapses a Blower motor overheated and thermal protection device deactivated motor possibly low voltage b GFCI tripped a Check that blower has sufficient ventilation and that the...

Страница 17: ...stamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should...

Отзывы: