TROUBLe SHOOTING GUIDe

If you believe the unit to be within the warranty period, you must contact 

Jason Customer Service: 

 

1-800-255-5766

 with the bath’s Product and Serial numbers before work is started.

 

ALL WARRANTY RePAIRS MUST Be AUTHORIZeD BY JASON BeFORe WORK IS STARTeD.

 
FOR SERVICE, ALWAYS CONTACT YOUR DEALER OR AUTHORIZED SERVICE CENTER

WARNING: Always turn off power at the main electrical service panel when servicing the bath.

WARRANTY ReGISTRATION: Register you product’s warranty online at 

www.jasoninternational.com.

MICrOsIlK

®

 PuMP sYsTeM

sYMPTOMs

POssIBle Causes

reCOMMenDeD aCTIOn

MicroSilk system fails  

to operate.

a)    No power to the MicroSilk unit.

b)    Motor is not plugged in.

c)    Touch Control — insufficient water 

in bath.

a)    Reset circuit breakers and GFCI if tripped. Check fuses and 

replace if bad.  

Check voltage at motor when control is on. If no voltage, the-

control is defective. If voltage is present, motor is defective.

b)    Make sure plug is fully inserted into the outlet.

c)    Fill bath to recommended level (4” above jets).

Pump operates, but no Micro-

bubbles are injected into water.

a)    Venturi clogged.

b)    Float valve no operating

a)    Refer to installer/dealer.

b)    Refer to installer/dealer.

Pump operates, but water is not 

being pumped.

a)    Suction or discharge blocked.

b)    Suction air leak. 

(System usually surges.)

a)    Remove obstruction.

b)    Make sure connection is tight on suction side of the pump.

Pump does not manually shut off.

a)    Digital or Touch Control defective.

a)    Refer to installer / dealer.

Pump shuts off by itself, or 
before set time elapses. 

a)    Pump motor overheated and thermal    
       protection device deactivated motor.  
       

(Possibly low voltage.)

b)    GFCI tripped.
c)    Water level fell below recommended  
       level.

a)    Make sure motor air cooling vents are not blocked, clear  
       and allow motor to cool down.

 (Check service & wire size.)

b)    Refer to Jason Customer Service.
c)    Fill to recommended level.

Pump does not turn off after set 

time elapses.

a)    Wiring error or control problem.

a)    Refer to installer / dealer.

Pump will not turn off when 

water is drained from the bath. 

a)    Water level sensor wires or ribbon-

cables are shorted.

a)    Inspect all sensor wires or ribbon cables for exposed or 

touching wires. Separate touching wires and replace ex-

posed wires. If pump continues, replace water level sensor.

Pump leaks at shaft.

a)    Damaged or defective shaft seal.

a)    Refer to installer / dealer.

LED Light will not operate

a)    Light bulb is  loose in the socket.

a)    Access light bulb and assure that it is properly installed in 

the socket

Содержание Forma MicroSilk-AirMasseur

Страница 1: ...ble for ensuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been avoided...

Страница 2: ...lower is required and should be designed to draw in indoor ambient air at a minimum of 72 F 22 C INSTALLATION INSTRUCTIONS 4 Install the drain and overflow assembly to the bath shell according to the...

Страница 3: ...ation Operation and Maintenance manual of the separately packaged MicroSilk hydrotherapy bath unit WARNING SYSTEM UNDER PRESSURE NEVER PERFORM MAINTENANCE WHILE SYSTEM IS RUNNING Figure 3 Figure 4 Not...

Страница 4: ...ed following E T L Guidelines During installation if remote mounting of the blower is desired or required the following procedures should be followed NOTE Do not remote mount the blower more than 15 f...

Страница 5: ...stallation is to be done by a Massachusetts licensed plumber 4 Standard Premier Edition MicroSilk AirMasseur Control Box 120v The MicroSilk generator unit may be shipped separate from the bath Follow...

Страница 6: ...and controls must be positioned horizontally and located to permit access for inspection and servicing If the MicroSilk generator unit is shipped separate from the bath the MicroSilk pump s power cord...

Страница 7: ...to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks 1 Before water testing...

Страница 8: ...ower cord will need to be plugged into the control box B Refer to the ELECTRICAL section of this manual for connecting the pump to the control box D Two pin terminal for installation of the water sens...

Страница 9: ...by Jason International Inc and features the ultimate in luxury bathing for the leisure bath industry The MicroSilk and blower control boxes must be properly connected for the bath to function correctl...

Страница 10: ...bath system The air bath system includes a variable speed 1 HP air blower with heater and three 3 massage modes Continuous Wave or Pulse The system also includes a Chromatherapy mood light Automatic O...

Страница 11: ...Operating The Signature Edition MicroSilk AirMasseur Touchpad section for details on activating this setting Filling and Draining Close the drain and fill the bath with water at least two 2 inches 50...

Страница 12: ...r Pressing the icon the first time starts the blower in the constant high speed mode Pressing the icon again begins the wave mode indicated by a slow flashing light Pressing the icon a third time will...

Страница 13: ...ring the purge idle period LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds to change modes The Light icon should remain li...

Страница 14: ...nsure a quick response on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment ALL WARRANTY REPA...

Страница 15: ...water a Venturi clogged b Float valve no operating a Refer to installer dealer b Refer to installer dealer Pump operates but water is not being pumped a Suction or discharge blocked b Suction air leak...

Страница 16: ...itself or before time elapses a Blower motor overheated and thermal protection device deactivated motor possibly low voltage b GFCI tripped a Check that blower has sufficient ventilation and that the...

Страница 17: ...stamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should...

Отзывы: