Appendix-31
PJRCD,
**
,3(Reception Status of Satellites in View, DGPS Correction Station Monitor Information)
Version 2.1
$PJRCD,GP,3, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, x*hh<CR><LF>
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 30
Version 2.3
$PJRCD,GP,3, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, x*hh
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
<CR><LF>
Version 4.0, IEC
$PJRCD,
**
,3, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, xx,x, x*hh
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
<CR><LF>
1: Taker
ID
GP: GPS or QZSS
GL:
GLONASS
GB: BeiDou (BDS)
2:
1st satellite PRN number
3:
1st satellite reception status (Refer to *1 for details)
24:
12th satellite PRN number
25:
12th satellite reception status (Refer to *1 for details)
* If there is data for less than 12 satellites, the remaining fields are either "00" or "0".(Version 2.1 )
26:
SBAS satellites 120 to 138 are represented by 33 to 51. (Version 2.3/4.0/IEC)
27:
SBAS satellite reception status (Refer to *1 for details) (Version 2.3/4.0/IEC)
28:
SBAS satellite spare Fixed at 00 (Version 2.3/4.0/IEC)
29:
SBAS satellite spare Fixed at 0 (Version 2.3/4.0/IEC)
* If there is data for less than 13 satellites, the remaining fields are either "00" or "0".
(Version 2.3/4.0/IEC)
30:
DGPS correction station operation status
7: = Correction station operation stopped
6: = Not monitoring correction station data
5 - 0: = Reserved as correction station data
* 1
.
Satellite reception status
0: Searching
1: Tracking
2: Tracking complete
3: Data recovery completed
4: Used for positioning
PJRCD,
GP,
8
(Beacon
Data)
$PJRCD,GP,8,XXXXXXXXX*hh<CR><LF>
1
1:
Type 16 message
The number of characters may vary slightly depending on the contents. Maximum of 90
characters.
Содержание JLR-8400
Страница 2: ......
Страница 17: ...xv Appearance of the Equipment NWZ 4620 Display Unit JLR 4350 GPS Sensor Unit ...
Страница 24: ......
Страница 28: ...1 4 1 4 Construction NWZ 4620 Display Unit Unit mm Mass Approximately 0 8 kg NWZ 4620 Desktop type ...
Страница 32: ...1 8 NQA 4351 Output Buffer Unit mm Mass Approximately 0 8 kg ...
Страница 34: ...1 10 NCZ 1663 Select Switch Stationary Unit mm Mass Approximately 0 2 kg ...
Страница 35: ...1 11 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg ...
Страница 36: ...1 12 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg ...
Страница 37: ...1 13 CQD 10 Junction Box Unit mm Mass Approximately 1 1 kg 4 φ7 5 Installation Screw M6 ...
Страница 38: ...1 14 NKG 104 Printer Unit mm Mass Approximately 2 1 kg ...
Страница 40: ...1 16 ...
Страница 44: ...2 4 ...
Страница 48: ...3 4 ...
Страница 148: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more ...
Страница 170: ...6 32 ...
Страница 172: ...7 2 ...
Страница 174: ...8 2 ...
Страница 178: ...9 4 ...
Страница 214: ......
Страница 216: ......
Страница 217: ......