4-77
4.15.8.4 Displaying the software version
The software version, serial number and bar code number of the display and sensor unit can be
displayed.
The serial number and bar code number of the sensor unit can be displayed.
1. Refer to "4.15.1 Changing to a maintenance mode" and display a maintenance menu.
1) Display
2. Select “MAINTENANCE”, “SOFT VERSION”, and “DISPLAY VER” in this order by using
.
2) Sensor
2. Select “MAINTENANCE”, “SOFT VERSION”, and “SENSOR VERSION” in this order by using
.
4.15.9 Performing a Master Reset (Reset)
The GPS sensor, display or both can be reset
When master reset is performed, the setting values are reset to the default values. It is recommended
to keep the records of the setting values before performing master reset.
However, the following items are not reset.
Model, RS-485ID, dimmer control unit setting, dimmer group
To reset the display, select "DISPALY" or EXCEPT FOR LIST"
Master reset can be selected for the following equipment.
1) DISPLAY RESET: The display unit is reset.
DISPLAY: Everything (include the waypoint and route list) will be reset
EXCEPT FOR LIST: Everything (except the waypoint and route list) will be reset
2) RECEIVER RESET: Sensor unit is reset.
3) ALL RESET: The sensor and display unit (including list) is reset
1. Refer to "4.15.1 Changing to a maintenance mode" and display the maintenance menu.
2. Press the
key to select "MASTER RESET," and press the
key.
3. Press the
key to select equipment and press the
key.
1) DISPLAY only (including list)
4. Select "DISPLAY RESET" and "DISPLAY" in order.
2) DISPLAY only (other than list)
4. Select "DISPLAY RESET" and "EXCEPT FOR LIST" in order.
3) SENSOR only
4. Select "RECEIVER RESET".
4) SENSOR and DISPALY
4. Select
"ALL
RESET".
Procedure
Procedure
Software version
Serial number
Bar code number
(Management number in the factory)
Содержание JLR-8400
Страница 2: ......
Страница 17: ...xv Appearance of the Equipment NWZ 4620 Display Unit JLR 4350 GPS Sensor Unit ...
Страница 24: ......
Страница 28: ...1 4 1 4 Construction NWZ 4620 Display Unit Unit mm Mass Approximately 0 8 kg NWZ 4620 Desktop type ...
Страница 32: ...1 8 NQA 4351 Output Buffer Unit mm Mass Approximately 0 8 kg ...
Страница 34: ...1 10 NCZ 1663 Select Switch Stationary Unit mm Mass Approximately 0 2 kg ...
Страница 35: ...1 11 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg ...
Страница 36: ...1 12 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg ...
Страница 37: ...1 13 CQD 10 Junction Box Unit mm Mass Approximately 1 1 kg 4 φ7 5 Installation Screw M6 ...
Страница 38: ...1 14 NKG 104 Printer Unit mm Mass Approximately 2 1 kg ...
Страница 40: ...1 16 ...
Страница 44: ...2 4 ...
Страница 48: ...3 4 ...
Страница 148: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more ...
Страница 170: ...6 32 ...
Страница 172: ...7 2 ...
Страница 174: ...8 2 ...
Страница 178: ...9 4 ...
Страница 214: ......
Страница 216: ......
Страница 217: ......