4.15.14 Setting Sensor Position / CCRP
·
You can set the ship size, CCRP position, and GPS sensor position.
·
The CCRP position and GPS position are set on a coordinate system with the center of the ship as
the point where the axes cross.
·
Set the ship size (ship length and width), and set the CCRP position and GPS sensor position.
·
The set CCRP position can be output to externally connected equipment. For output, refer to "4.15.4.1
Setting transmission ", and select "PJRC,SAP,GP" or "POS" as the output sentence.
To output to external equipment, the equipment must have CCRP send / receive functionality.
·
CCRP cannot be set from a sub-display. Set CCRP from the main display.
1. Refer to "4.15.1 Changing to a maintenance mode"
and display the maintenance menu.
2. Press the
key to select "CCRP"
and press the
key.
3. Press the
key to select the ship size ("BEAM", "LENGTH"), and enter the shi size.
4. Press the
key to select the sensor position ("SENSOR X/Y/Z"), and enter the sensor
position
5. Press the
key to select the CCRP position ("CCRP X/Y/Z"), and enter the CCRP position
The CCRP position can be received. If the set position and received position differ, a pop up alert
will occur, so please perform the settings again.
4.15.15 Calculating Trip Distance
Trip distance is calculable from a ship speed and
elapsed time.
Two trip is simultaneously calculable.
In order to do trip calculation, it is necessary to select a
distance screen by screen selection.
1. Press the
key to sect "START" of TRIP1 or "START" of TRIP2 and press the
key.
2. "RUN" blinks and calculate trip.
3. Press the
key to select "END" and press the
key.
Trip distance is displayed until it selects "START" again.
Procedure
Y
X
Origin (0,0,0)
Z
CCRP (X,Y,Z)
Sensor (X,Y,Z)
Procedure
Trip will be cleared when a power is turned OFF.
Supplement
Содержание JLR-8400
Страница 2: ......
Страница 17: ...xv Appearance of the Equipment NWZ 4620 Display Unit JLR 4350 GPS Sensor Unit ...
Страница 24: ......
Страница 28: ...1 4 1 4 Construction NWZ 4620 Display Unit Unit mm Mass Approximately 0 8 kg NWZ 4620 Desktop type ...
Страница 32: ...1 8 NQA 4351 Output Buffer Unit mm Mass Approximately 0 8 kg ...
Страница 34: ...1 10 NCZ 1663 Select Switch Stationary Unit mm Mass Approximately 0 2 kg ...
Страница 35: ...1 11 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg ...
Страница 36: ...1 12 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg ...
Страница 37: ...1 13 CQD 10 Junction Box Unit mm Mass Approximately 1 1 kg 4 φ7 5 Installation Screw M6 ...
Страница 38: ...1 14 NKG 104 Printer Unit mm Mass Approximately 2 1 kg ...
Страница 40: ...1 16 ...
Страница 44: ...2 4 ...
Страница 48: ...3 4 ...
Страница 148: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more ...
Страница 170: ...6 32 ...
Страница 172: ...7 2 ...
Страница 174: ...8 2 ...
Страница 178: ...9 4 ...
Страница 214: ......
Страница 216: ......
Страница 217: ......