13. Use (2) 3/8” x 4” bolts, (2) 2” plastic spacers (JM0002444), and (2) 3/8” serrated flange nuts to fasten down
pressure relief valve bank (JM0034806) to the front hydraulic hose guard. Connect hose (JM0041687) from
pressure gauge to down pressure relief valve bank.
14. Run the (2) 1/2” x 168” hoses (JM0073122) up the tongue and connect one to the PWM control valve
(JM0059223) and one to a 1/2” Male JIC x 1/2” Male JIC; Straight fitting (JM0041452). On the other side of the
fitting and the PWM valve connect (2) 1/2” x 180” hoses (JM0073123)and run it from the top of the tongue
along the frame of the applicator all the way to the hydraulic pump on the right/passenger side. Later in this
process, these hoses will connect to the pump. Mount the front hose guard using (4) 3/8” x 1” serrated flange
bolts and (4) 3/8” serrated flange nuts. Mount the PWM valve to the top and inside of the tongue shroud using
(2) 5/16”-18 x 2-1/2” Gr5 Z Hex Bolts and (2) 5/16”-18 Gr5 Z SF Hex Nuts as shown in the image below.
Frame