GO-5000M-PGE-UV User Manual (Ver. 1.2)
Main Functions
- 75 -
Delayed Readout Function
The images captured by Frame Start trigger can be stored inside the camera and read out by
Acquisition Transfer Start trigger. Up to 7 frames at 8-bit operation can be stored. For 10-bit/12- bit
operation, it is 3 frames.
Command
Setting
Description
Trigger
Selector
Acquisition Transfer Start
Select the Trigger Selector at Acquisition Transfer Start to
operate this function.
Trigger Mode On
Refer to
Trigger
Source
Select the source to be used
Trigger
Activation
Select the polarity of the source
to be used.
Operation Timing