Sequence Mode
This mode allows the user to define a preset sequence of up to 10 images, each with its own ROI,
exposure time and gain values. This mode has two operation modes.
Mode Selected
Index Selection method
Trigger
Sequence
Select the index by using the Frame Start trigger signal. (The setting index can be
determined by the Next Index setting.)
Command
Sequence
Select the index number to assign directly by using the Command Sequence Index
command.
Primary settings to use this mode
l
Trigger Mode: ON
l
Exposure mode: Timed
l
Video Send Mode: Trigger Sequence or Command Sequence
Read Out Mode
Minimum Trigger Interval
Full
45.2 ms + Exposure time
ROI 2/3 (Height=1365)
30 ms + Exposure time
ROI 1/2 (Height=1024)
22.4 ms + Exposure time
ROI 1/4 (Height=512)
11.4 ms + Exposure time
ROI 1/8 (Height=256)
5.8 ms + Exposure time
1/2V Binning
22.4 ms + Exposure time