GO-5000M-PGE-UV User Manual (Ver. 1.2)
Main Functions
- 59 -
The effect of the combination of Exposure Mode, Trigger Option and Trigger Mode is as follows.
Exposure
Mode
Trigger
Option
Trigger Mode (Frame
Start)
Operation
OFF
N/A
N/A
Free-running operation. Exposure control by Exposure
Time is not possible.
Timed
OFF
OFF
Free-running operation. Exposure control by Exposure
Time is not possible.
ON
Timed (EPS) Operation. Exposure can be controlled by
Exposure Time.
RCT
ON
RCT Operation. Exposure can be controlled by Exposure
Time
Trigger
Width
N/A
ON
Exposure is controlled by the pulse width of the external
trigger
Exposure Time
This command is effective only when Exposure Mode is set to Timed. It is for setting exposure time.
The setting step for exposure time is 1 μsec per step.
l
Minimum: 10 μsec
l
Maximum: 8 seconds
Note:
Noise may make image unusable after 1 second)
ExposureAuto
This is a function to control the exposure automatically. It is effective only for Timed. JAI ALC
Reference controls the brightness. There are two modes, OFF and Continuous.
l
OFF
: No exposure control
l
Continuous
: Exposure continues to be adjusted automatically
In this mode, the following settings are available.
l
ALC Speed: Rate of adjustment can be set (Common with GainAuto)
l
ExposureAuto Max: The maximum value for the exposure time to be controlled can be set
l
ExposureAuto Min: The minimum value for the exposure time to be controlled can be set
l
ALC Reference: The reference level of the exposure control can be set (Common with GainAuto)
l
ALC Area Selector: The portion of the image used for controlling exposure can be set (Common
with GainAuto)
Содержание GO-5000M-PGE-UV
Страница 46: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 46 Output Timing Vertical Vertical Timing ...
Страница 55: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 55 How to Determine the Maximum Frame Rate ...
Страница 60: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 60 ALC Channel Area ...
Страница 74: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 74 Multi ROI Setting Example ...
Страница 86: ...GO 5000M PGE UV User Manual Ver 1 2 Miscellaneous 86 Spectral Response ...