GO-5000M-PGE-UV User Manual (Ver. 1.2)
Main Functions
- 62 -
Trigger Source
The following signals can be used as the trigger source signal.
Trigger Source
Item
Description
Low
Connect LOW level signal to the selected trigger operation (Default setting)
High
Connect HIGH level signal to the selected trigger operation
Soft Trigger
Connect Soft Trigger signal to the selected trigger operation. Trigger can be input manually
by the execution of the software trigger. Trigger software is available on each trigger
source.
PulseGenerator0 Connect Pulse generator 0 signal to the selected trigger operation
User output 0
Connect User output 0 signal to the selected trigger operation
User output 1
Connect User output 1 signal to the selected trigger operation
Line 5 - OPT IN 1
Connect OPT IN 1 signal to the selected trigger operation
NAND 0 Out
Connect NAND 0 OUT signal to the selected trigger operation
NAND 1 Out
Connect NAND1 OUT signal to the selected trigger operation
Action 1
Connect Action 1 OUT signal to the selected trigger operation
Action 2
Connect Action 2 OUT signal to the selected trigger operation