GO-5000M-PGE-UV User Manual (Ver. 1.2)
Main Functions
- 68 -
Primary settings to use this mode
l
Exposure Mode: Timed
l
Trigger Selector: Frame Start
l
Trigger Mode: ON
l
Trigger Option: RCT
If ALC control is used together with RCT mode, then
l
Exposure auto: Continuous
l
Gain Auto: Continuous
Minimum interval of the trigger
Read Out Mode
Minimum Trigger Interval
Full
45.2 ms + Exposure time + 271 μs
ROI 2/3 (Height=1365)
30 ms + Exposure time + 271 μs
ROI 1/2 (Height=1024)
22.4 ms + Exposure time + 271 μs
ROI 1/4 (Height=512)
11.4 ms + Exposure time + 271 μs
ROI 1/8 (Height=256)
5.8 ms + Exposure time + 271 μs
1/2V Binning
22.4 ms + Exposure time + 271 μs
Video Send Mode
This camera has a Video Send Mode, and it includes the following operations.
Mode
Selected
Index Selection method
Normal
Normal operation
Multi ROI
Up to 5 ROI images can be set up. Each image is output independently.
Trigger
Sequence
Up to 10 indexes can be set for ROI, Exposure Time and Gain. Select the index by using the
Frame Start trigger signal.
Command
Sequence
Up to 10 indexes can be set for ROI, Exposure time and Gain. Select the index number to assign
directly by using the Command Sequence Index command.
Delayed
Readout
Up to 7 frames can be stored (8-bit). Each image can be output by Acquisition Transfer Start
trigger timing.
Содержание GO-5000M-PGE-UV
Страница 46: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 46 Output Timing Vertical Vertical Timing ...
Страница 55: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 55 How to Determine the Maximum Frame Rate ...
Страница 60: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 60 ALC Channel Area ...
Страница 74: ...GO 5000M PGE UV User Manual Ver 1 2 Main Functions 74 Multi ROI Setting Example ...
Страница 86: ...GO 5000M PGE UV User Manual Ver 1 2 Miscellaneous 86 Spectral Response ...