![JAI GO-5000M-PGE-UV Скачать руководство пользователя страница 65](http://html.mh-extra.com/html/jai/go-5000m-pge-uv/go-5000m-pge-uv_user-manual_631513065.webp)
GO-5000M-PGE-UV User Manual (Ver. 1.2)
Main Functions
- 65 -
Timed Mode
This mode allows a single image frame to be captured with a preset exposure time by using the
external trigger. Additional settings determine if the trigger pulse can be accepted during the exposure
period.
Primary settings to use this mode
l
Trigger Mode = ON
l
Trigger Source: Opt IN (6p connector)
l
Trigger Option: Off
l
Optical Filter Selector: 10μs
Readout Mode
Minimum Trigger Interval
Full
44.843 ms
ROI 2/3 (Height=1365)
29.962 ms
ROI 1/2 (Height=1024)
22.532 ms
ROI 1/4 (Height=512)
11.377 ms
ROI 1/8 (Height=256)
5.8 ms
1/2V Binning
22.532 ms
t1
t2
t3
10μs (Min)
61 μs
5L to 6L