![JAI GO-5000M-PGE-UV Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/jai/go-5000m-pge-uv/go-5000m-pge-uv_user-manual_631513070.webp)
GO-5000M-PGE-UV User Manual (Ver. 1.2)
Main Functions
- 70 -
Trigger Sequence Mode Basic Timing
In this mode, as each trigger input is received, the image data associated with the next index within the
preset sequence is output. In the trigger sequence mode, it is not possible to input the trigger while the
current index is executing.
The sequence index table always starts at Index 1 and changes to next index which is preset in the
next index setting after the current index is completed.
Behavior of Sequence trigger
Behavior if Video Send Mode is set to Trigger Sequence