AD-131GE
60
10.6.5 Smearless mode
This function can be used to reduce the smear coming from bright areas or objects within the
image. This is effective for both EPS and PWC trigger modes. Before the accumulation starts,
any charge that is stored in the pixel is dumped by a high-speed transfer. This can reduce the
smear that is visible directly above a bright object in the image, but the smear showing below
the object is unaffected.
At the falling edge of the trigger pulse the high speed transfer starts. This period is 6.34ms
which is 196L. Thereafter the residual charge in the horizontal CCD register is read out in 1L
and the new exposure starts. This function is available for both full scan and partial scan.
This function can be set if Smearless Enable in JAI Acquisition Control is set at True.
10.6.5.1 Sync=Sync, LVAL Async, Smearless Enable=True, EPS trigger
t1
t2
t3
t4
t5
t6
V-Binning Off
0.2L(6.03
μ
s)
2.8L
~
3.8L
977L
966L
8L
2L
V-Binning On
0.3L(11.86
μ
s)
1.8L
~
2.8L
489L
483L
4L
1L
Fig. 47 Smearless, EPS trigger timing chart
Содержание AD-131GE
Страница 80: ...AD 131GE 79 ...
Страница 81: ...AD 131GE 80 ...
Страница 82: ...AD 131GE 81 ...
Страница 84: ...AD 131GE 83 ...
Страница 91: ...AD 131GE 90 Change History Month Year Revision Changes July 2012 1 0 New issue ...