AD-131GE
25
Fig. 20
.
Restriction by polarity setting
7.5.6 Caution when the software trigger is used
The AD-131GE has the following restriction when using the software trigger.
1) The input port of GPIO, Camera 0 and Camera 1 have software trigger 0 to 3, respectively.
However, the output port of GPIO has only one software trigger 0 to 3.
Therefore, the function is described in the figure 21.
It is recommended to use a different software trigger for Camera 0 and Camera 1.
C am era 1
Fram e Start
[T rigger Activation] Setting
=
“
Falling E dge
”
C am era 0
Fram e Start
[Trigger Activation] Setting
=
“
R ising E dge
”
T TL In 1 I/F
Positive Pulse
N egative Pulse
or
Positive Pulse
F alling Edge
N egative Pulse
F alling Edge
Positive Pulse
R ising Edge
N egative Pulse
R ising Edge
T TL In 1
I/F
Initialized by Camera 0
Initialize
Recognized
Recognized
Recognized
Not recognized
①
②
①
①
②
②
Camera 1
Frame Start
Trigger
GPIO
Host PC
Camera 0
Camera 1
Camera 0
Software Trigger 0
I/F
Camera#0
Frame Start
[
Activation ]
=
―
Rising Edge
‖
TG
Camera 0
Frame Start
Trigger
Software Trigger0
Camera1
Software Trigger 0
Command
Command
AD-132GE
Example of the restriction if the frame start trigger for Camera 0 and Camera 1 is set to TTL In1
[Restriction]
In Sync Mode = Async, TTL In1 I/F is initialized using Trigger Activation of Camera 0 as the reference. If the trigger set in Trigger
Activation is applied to Camera 1 first, Camera 1 cannot recognize the trigger and misses one frame. (Case
②
)
Example for Frame Start Trigger