AD-131GE
86
13.2. Specification Table
Specifications
AD-131GE
Optical system
1/3 inch type F2 prism
Scanning system
Progressive scan
Synchronization
Int. X-tal
Frame Rate Full scan
31.484 frames / sec. Progressive (966 lines/frame)
Pixel clock
51.324MHz
Line frequency
30.918 KHz (1660 pixel clocks / line)
Image sensor
1/3 inch Bayer color IT CCD ICX447
Sensing area
4.86 (H) x 3.63 (V) mm
Cell size
3.75 (H) x 3.75(V) µm
Active pixels
1296(H) x 966 (V)
Pixels in Video output
Full
Partial
1296 (h) x 966 (v) 31.484 fps. H = 30.918 kHz
Scan height 8 to 966 lines,
In conjunction with ROI, if JAI Partial Scan is set to ON, Offset Y and Height is
automatically set.
Output readout
Sync, Async, High S/N, High Dynamic Range, High Frame Rate
Sensitivity on sensor
0.1 lux
Max. Gain, Shutter OFF, 50% Video Level
S/N ( dB)
More than 54dB 10-bit
output
Iris video output, Analog
0.7 V p-p (without Sync)
Digital Video Output
Via RJ-45-1(GigE1), RJ-45 (GigE-2)
Mono_8bit, Mono_10bit, Mono_12bit, Mono_10bit_Packed, Mono_12bit_Packed
Input signals
(TTL/75Ω) x2
, LVDS x 1 Hirose 6 pin
OPT x2 HIROSE 12-pin
Output signals
TTL x 1 Hirose 6 pin
OPT x 2 Hirose 12 pin
Gain
Manual gain : 0dB to +21dB (0.035dB / Step)
AGC : 0dB to +21dB (Gain Auto = Continuous)
AGC range can be set in units from 0 (min.) to 539 (max.)
LUT/Gamma
1.0(OFF)/0.9/0.8/0.75/0.6/0.55/0.5/0.45/LUT
Shading compensation
flat shading
Blemish compensation
Built in
GPIO Module
Input /Output switch
Clock
Generator(four)
Pulse generator
(Four)
Configurable 25-in / 14-out switch
12 bit counter based on pixel clock
20-bit counter programmable for length, start point, stop point , repeat
Hardware Trigger mode
Edge Pre-select, Pulse width control, RCT, Frame delay (EPS/PWC)
Sequence EPS, PIV
OB area transfer mode
ON / OFF
In case of ON, 970 lines in vertical and 1312 clocks in horizontal are output.
Event message
Exposure start, Exposure end, Trigger IN, Video start, Video end
Electronic Shutter
Exposure Time Abs
Pulse width control
GPIO plus Pulse width
Auto shutter
11.49 µs to 31.761ms(0.4L to 982L in 1L step)
1/13,000 (2.4L) to Max. 2 sec
fine setting with GPIO and pulse width control
95L to 982L
Accumulation
LVAL synchronous or LVAL asynchronous automatic selection or manual
Control interface
Gigabit Ethernet (IEEE802.3, ATA GigE Vision Standard) 2 lines
Functions controlled via GigE
Vision Interface
Shutter, Gain, Black Level, Trigger mode, Read out mode,
GPIO setup, ROI (GenICam mandatory functions)
GigE Vision Streaming Control
Packet size, Delayed (Frame) read-out, inter-packet delay
Jumbo frame can be set at max. 16K (16020), Default packet size is 1476 Byte.