AD-131GE
70
10.6.10.1 Setting parameters
In order to execute Multi ROI operation, it is necessary to set ROI mode, and ROI size and offset
in ROI selector. There is one set each for Camera #0 and Camera #1.
ROI Mode
:
Can be set 1 to 5. This sets the number of ROIs. For multi ROI operation, this should be set
from 2 to 5. A total of 5 ROI can be set.
ROI Selector
:
In ROI Selector, there is ROI 1 to 5 and each has Width, Height, Offset X and Offset Y
settings.
The following is how the settings appear in the GUI.
If ROI Mode is set to 1, only one ROI can be set.
In order to use Multi
ROI, it should be set at 2 or more. A maximum of 5 ROIs
can be set.
The size for each ROI can be set by ROI selector.
10.6.10.2 Initial parameters
Camera 0
Camera 1
ROI Mode
1
1
ROI Selector
Width
Height
Offset X
Offset Y
Width
Height
Offset X
Offset Y
ROI 1
1296
966
0
0
1296
966
0
0
ROI 2
1296
966
0
0
1296
966
0
0
ROI 3
1296
966
0
0
1296
966
0
0
ROI 4
1296
966
0
0
1296
966
0
0
ROI 5
1296
966
0
0
1296
966
0
0
10.6.11 Optical Black transfer mode
It is possible for the user to decide whether the optical black (OB) portion of the image will be
transferred or not. The optical black part can be used for black reference in the application
software. By setting
―
OB Transfer Enable
‖
to True, the width max is changed from 1296 to
1312 and the height max is changed to 966 to 970
which includes OB for 16 horizontal pixels