10.6.7.6 PIV trigger minimum interval
SYNC
Mode
Minimum Trigger Interval
(
Line
)
at Binning Vertical=1
1
L=32.344
μ
s
at Binning Vertical=2
1L=38.189
μ
s
SYNC
Mode=
SYNC
LVAL
ASYNC
V-Binning
Off
{(([PIV Exposure Time]x8)+[PIV In294) /
[1LineH.clock
:
1660]}
+
(Frame interval in continuous
mode[L]×2) + 4 L
“
round off after the decimal point
”
V-Binning
On
{(([PIV Exposure Time]x8)+[PIV In596) /
[1LineH.clock
:
1660]}
+
(Frame interval in continuous
mode[L]:494×2) + 4 L
“
round off after the decimal point
”
(Reference)
In PIV Mode 1,2,3 and if [JAI Partial Scan]=False is set, the minimum Trigger interval is as
follows:(Frame interval [L] in continuous mode = 982 Line)
[PIV Mode 1 Minimum Trigger interval]
≧
1968 Line
[PIV Mode 2 Minimum Trigger interval]
≧
1969 Line
[PIV Mode 3 Minimum Trigger interval]
≧
1969 Line
[PIV Mode 4
:
PIV Exposure & PIV Interval values are set at maximum; minimum Trigger
interval]
≧
1989 Line
[PIV Mode 4
:
PIV Exposure & PIV Interval values are set at minimum, minimum Trigger
interval]
≧
1968 Line
Содержание AD-131GE
Страница 80: ...AD 131GE 79 ...
Страница 81: ...AD 131GE 80 ...
Страница 82: ...AD 131GE 81 ...
Страница 84: ...AD 131GE 83 ...
Страница 91: ...AD 131GE 90 Change History Month Year Revision Changes July 2012 1 0 New issue ...