![JAI AD-131GE Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/jai/ad-131ge/ad-131ge_user-manual_631522047.webp)
AD-131GE
46
10.2. Trigger Control
10.2.1 Trigger Selector (Trigger Mode)
This is the function to set the trigger operation. This will set how to control the output and the
exposure.
Frame Start
Trigger
Set the frame start externally
Transfer Start
Stream
Set the stream start externally
10.2.1.1 Acquisition
This is the trigger function to control the output. This controls AcquisitionStart and
AcquisitionEnd. A description of the configuration process is as follows:
AcquisitionStart trigger: Set whether the capture start is to be controlled
externally or not.
TriggerMode On
:
After AcquisitionStart command is input, input the
signal selected by AcquisitionStart trigger as the trigger,
and make AcquisitionActive effective.
TriggerMode Off
:
AcquisitionStart command is input. It makes
AcquisitionActive effective regardless of
AcquisitionStart trigger.
AcquisitionEnd trigger: Set whether the end of the capture is to be
controlled externally or not.
TriggerMode On
:
While AcquisitionActive is effective, input the signal
selected by AcquisitionEnd as the trigger, and make
AcquisitionActive invalid.
TriggerMode Off
:
AcquisitionStart command is input. It makes
AcquisitionActive invalid regardless of the trigger
source.
10.2.1.2 Exposure
These commands are used for setting the exposure control.
FrameStart is used for trigger input.
If ExposureMode is set to Timed or TriggerWidth except OFF, the combination of the
ExposureMode setting and FrameStart setting will determine the type of exposure
and whether triggering is OFF or ON.
The following table shows the combination and the operation.
TriggerSelector
ExposureMode
Frame
Start
Operation
Previous JAI
trigger name
(for reference)
OFF
OFF or
ON
Trig OFF(Free run)
No Exposure Control
Trigger
OFF
Timed
OFF
Trig OFF(Free run)
Exposure Control
Is possible
Trigger
OFF
ON
Trig On
EPS
TriggerWidth
OFF
Trig OFF(Free run)
No Exposure Control
Trigger
OFF
ON
Trig On
PWC
Содержание AD-131GE
Страница 80: ...AD 131GE 79 ...
Страница 81: ...AD 131GE 80 ...
Страница 82: ...AD 131GE 81 ...
Страница 84: ...AD 131GE 83 ...
Страница 91: ...AD 131GE 90 Change History Month Year Revision Changes July 2012 1 0 New issue ...