![JAI AD-131GE Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/jai/ad-131ge/ad-131ge_user-manual_631522049.webp)
AD-131GE
48
If FrameStart in TriggerSelector is
“
ON
”
, this functions as the
EPS mode.
Note: JAI Pre-Dump can be available by using TriggerOption.
TriggerWidth
:
This mode controls the exposure time by the pulse width.
If FrameStart in TriggerSelector is
“
OFF
”
,
The camera operates in Free Run.
If FrameStart in the TriggerSelector is
“
ON
”
, this functions as
the PWC mode.
The following is the table for the combination of ExposureMode and TriggerControl
and its function.
TriggerSelector
ExposureMode
Frame
Start
Operation
Previous JAI
trigger name
(for reference)
OFF
OFF or
ON
Trig OFF(Free run)
Exposure controllable
Trigger
OFF
Timed
OFF
Trig OFF(Free run)
Exposure control is
possible
Trigger
OFF
ON
Trig On
EPS
TriggerWidth
OFF
Trig OFF(Free run)
No Exposure control
Trigger
OFF
ON
Trig On
PWC
10.3.2 Exposure Time
This is effective only if ExposureMode is set to
“
Timed
”
. This command can set the exposure
time.
The setting can be done in 1
μ
s / step.
Minimum:
11.49
μ
s
Maximum:
31.76msec
10.3.3 Exposure Auto
This is auto exposure control function and is effective only in the
“
Timed
”
mode.
The
reference video level is controlled by JAI AGC Reference. ExposureAuto includes OFF, Once
and Continuous modes.
The following detailed settings are aslo possible.
ExposureAuto speed:
The reaction speed can be controlled
ExposureAuto Max:
Set the maximum exposure time
ExposureAuto Min:
Set the minimum exposure time
GainAutoReference:
Set the reference video level for operation
10.4. Action Control
ActionControl is used to activate the specific functions of multiple cameras on the same
network at the same time. For instance, it can be used to trigger multiple cameras at the
same time.
ActionControl appears as two inputs (Action 1, Action 2) and is connected with 6 Triggers,
CounterReset of the counter, CounterTrigger and Timer. If ActionControl is used, the input
source to the trigger should be set to Action 1 or Action 2 in advance.