8
CHAPTER 4 - OPERA
TION AND ADJUSTMENTS
J-600 ELECTRIC
Mechanical agitator / Filling unit
> Mechanical agitator
∙ This device provides a better homogenization
to the chemical mixture, thus reducing clogging
of nozzles and filter.
agitator´s puley
> Filling unit
filling unit valve
filling
intermediate
working
clean water source
4
3
2
1
sprayer´s tank
valve rod
filling unit
1- Set the spout valve lever (A) to turn off.
2- Put 5.28 gallons of water in the tank.
3- Connect the filing unit hose (3) through quick
fitting to the filling unit valve (2) and keep the fill-
ing unit (4) at the same height of the valve (2).
4- Set the lever of the filling unit valve (2) to the
intermediate position so that the hose (3) is com-
pletely full of water.
5- Set the filling unit valve lever (2) to the working
position.
6- Put the filling unit (4) in the clean water
source.
7- Engage the PTO with 540 rpm.
8- Set the filling unit valve lever (2) to the filling
position.
9- After filling, set the filling unit lever (2) back to
the working position.
ATTENTION!
Only fill the sprayer's tank in plac-
es appropriate for this purpose or
through appropriate vehicles (trucks,
trailers, etc.). Do not collect water
from rivers, lakes, dams, streams,
brooks, etc. by using the sprayer's re-
turn system.
A