3
CHAPTER 4 - OPERA
TION AND ADJUSTMENTS
J-600 ELECTRIC
Suction filter / Pump / Flow rate regulating valve
∙
Located between the tank and pump, the suc-
tion filter is specifically designed to prevent dirt or
impurities from reaching the pump.
∙
It has a quick shut off valve which allows easy
filter cleaning, filtering elements changing and/
or pump maintenance. This valve should always
remain open while the sprayer is running. If it re-
mains closed, the mechanical seal of the pump
can be damaged.
∙
The pumps mounted to Jacto cannon sprayers
have flow rate ranging from 29.06 up to 39.63
gpm.
∙
These pumps can be single-stage (one rotor) or
dual-stage (two rotors), as shown in the section
PRESENTATION OF SPRAYER - TECHNICAL
SPECIFICATIONS.
∙
The combination of a high flow rate pump
with low power consumption allows the use of
a powerful fan, making this cannon sprayer one
of the most efficient unit as regards operational
performance.
> Pump
centrifugal pump
(dual-stage)
> Suction filter
FVS -102
shut off valve
∙
This valve allows calibrating your cannon
sprayer by setting the lever within a scale from 0
to 4, giving flow rates ranging from 2.64 to 8.72
gpm.
> Flow rate regulating valve
flow rate
regulating
valve