23. Trouble-shooting
Any remedial action to defective electrical equipment must be carried out by a
qualified electrician!
Malfunction/ Error
Cause
Remedy
mains voltage connected and
loss of supply voltage
Check mains fuse,
master switch in pos.´ON´/
Check mains cable
mains Control
is not lit
Wire buckling between wire feed
rollers and guide tube
excessive contact pressure of wire
feed rollers
see chapter 20 Wire feed
distance between wire feed rollers
and guide tube too far
check distance / realign guide tube
Irregular wire feed
bad uncoiling of wire
check / refit wire coil
wire-holding arbour runs heavily
check wire-holding arbour
wrong wire feed roller
see chapter 20 Wire feed
dirty / defective wire guide tube or
spiral
see chapter 20 Wire feed
clogged / defective current contact
tip
clean / exchange current contact
tip
dirty / rusty welding wire
exchange welding wire
wire guide tube misaligned with
wire feed roller groove
see chapter 20 Wire feed
Porous weld seam
work piece surface polluted (paint,
rust, oil, grease)
clean surface
no shielding gas (solenoid valve
not opening)
check / exchange solenoid valve
insufficient shielding gas
check shielding gas at pressure
reducer
check gas line for leakage using
meter tube
gas nozzle polluted
clean gas nozzle
24. Automatic error diagnostics
In the case of error, error codes are shown in displays.
There are 2 types of errors:
- Error messages are deleted automatically (short-term errors)
- An error must be deleted by switching the welder on and off again (major fault / defect)
Error number
Error description and possible diagnosis
E0.0
VOLTAGE SUPPLY ERROR
This error can only occur when switching on the unit, not during normal operation of the
welding unit.
This error is shown only on the display, but not saved in the error memory.
Deleting an error by switching the unit on and off again.
E0.1
REDUCED VOLTAGE AND OVERVOLTAGE
Error message deletes automatically
E0.2
OVERVOLTAGE
Error message deletes automatically
E0.3
REDUCED VOLTAGE
Error message deletes automatically
E0.4
OVERLOAD CURRENT
Error message deletes automatically
E0.5
REMOTE CONTROL
Lack of remote control power supply
Delete this error by switching the unit off and on again.
Содержание ProPuls 320 Compact
Страница 2: ......
Страница 66: ...ProPuls 320C Operating manual Page 62 25 Ersatzteile spare parts Frontansicht front view...
Страница 68: ...ProPuls 320C Operating manual Page 64 Seitenansichten side view...
Страница 73: ...ProPuls 320C Operating manual Page 69 27 Schwei programme Program table...
Страница 74: ...ProPuls 320C Operating manual Page 70...
Страница 75: ......