ProPuls 320C
Operating manual
Page 59
Error number
Error description and possible diagnosis
E0.6
WATER COOLING UNIT
The machine wait for a signal from the cooling unit.
- Check the hoses
- Contact JÄCKLE customer service
Delete this error by switching the unit off and on again.
E0.7
WF MOTOR ERROR
Motor in the wire feed housing not functioning.
- Check motor
- Contact JÄCKLE customer service
Delete this error by switching the unit off and on again.
E0.8
WIRE FEEDER MISSING
The machine waits for a signal from the wire feeder.
- Check intermediate hose assembly
- Contact JÄCKLE customer service
Delete this error by switching the unit off and on again.
E0.9
CAN ERROR
The CAN communication between the machine and the wire feeder has been
interrupted.
- Check intermediate hose assembly
- Contact JÄCKLE customer service
Delete this error by switching the unit off and on again.
T°C
Excessive temperatures
The machine has switched off due to overheating.
Let the machine rest with the fan running until the message disappears.
Error message deletes automatically
H2o
COOLING UNIT PRESSURE
The cooling unit is recognised by the welder but the pressure switch is not functioning.
- Check the water level and fill if required.
- Check the lines
- Check to see if the pressure switch is functioning
Delete this error by switching the unit off and on again.
E1.0
CONFIGURATION FILE IS MISSING (configuration file is missing)
Internal error in the software
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E1.1
USER SETTINGS MISSING
Internal software error
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E1.2
TORCH SETTINGS MISSING
Internal software error
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E1.3
CALIBRATION SETTINGS MISSING (calibration file missing)
Internal software error
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E1.4
Not used
E1.5
Not used
E1.6
ELECTRODE SETTINGS MISSING
Internal software error
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
E1.7
TIG SETTINGS MISSING
Internal software error
- Contact JÄCKLE customer service
This error is shown only on the display, but not saved in the error memory.
Delete this error by switching the unit off and on again.
Содержание ProPuls 320 Compact
Страница 2: ......
Страница 66: ...ProPuls 320C Operating manual Page 62 25 Ersatzteile spare parts Frontansicht front view...
Страница 68: ...ProPuls 320C Operating manual Page 64 Seitenansichten side view...
Страница 73: ...ProPuls 320C Operating manual Page 69 27 Schwei programme Program table...
Страница 74: ...ProPuls 320C Operating manual Page 70...
Страница 75: ......