![IXSEA TT801 Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/ixsea/tt801/tt801_user-manual_2098858087.webp)
Remote Control System TT801 – User Guide
MU-TT801-AN rev.6 September 2009
79
FUNCTIONAL SPECIFICATIONS
Function / Code
TT801/TT301 TT201
Sequence
ON FR1-FR2
2842 BIT0 + BIT1 + 42
FT0
OFF FR1-FR2-PINGER(ST)
2843 BIT0 + BIT1 + 43
FT0
RELEASE 1
2844 BIT0 + BIT1 + 44
FT0
⇒
FT5
DIAGNOSTIC
2845 BIT0 + BIT1 + 45
FT0
⇒
FT7 Measure
delay
:
3
s
Verticality Offset :
10
s
WINDOW
(
↔
ARM)
2841 BIT0 + BIT1 + 41
FT0
Wait time
:
15
s
Active time
:
15
s
ON FR1-OFF FR2(W)
2883 BIT0 + BIT1 + 83
FT0
ON FR2-OFF FR1(W)
2884 BIT0 + BIT1 + 84
FT0
PINGER (W)
2894 BIT0 + BIT1 + 94
FT0
⇒
FT4 Pulse
width
:
9.14
ms
Recurrence
:
1
s
(W) : Code active only during WINDOW active time
(ST) : Default operating mode at power up