Remote Control System TT801 – User Guide
MU-TT801-AN rev.6 September 2009
43
III.4.5 C
ASE OF THE
P
RESSURE
M
EASUREMENT
The access to this sub-menu is allowed by pressing
2
key in
TX / RX settings
menu and
then by pressing
3
key in the
DATABASE
menu. A window opens with the first instrument
available in the database as in following examples:
DATABASE / ERASE
IDENT :
005
TYPE :
RT8xx
TRANSMIT TYPE :
ARM + CMD
CODE ARM :
DCFE
CMD : DCFF
RECURRENCE : MANU
COMMAND :
RELEASE
SCROLL = CHOICE
ENTER = VALID
Step 1
DATABASE / ERASE
IDENT :
012
TYPE : RT8xx
TRANSMIT TYPE :
IIF
FREQ :
12 kHZ
RECURRENCE : AUTO
RATE :
2
sec.
SCROLL = CHOICE
ENTER = VALID
Step Action
1.
Select the new device to be loaded with
SCROLL
key.
TT801 displays the main parameters of the instruments selected.
To correct the ID, use the
CLEAR
key:
A blank window opens with requirement for an ID number.
You must then type in an existing saved ID number and confirm by pressing the
ENTER
key to display the configuration of the selected instrument.
If the selection is not valid, the message “
ID NOT REGISTRED
” is prompted and you
are required to exit (
HOME
key) or to type in a new ID number.
Then, press
ENTER
key to confirm the selection
At completion of the operation, TT801 displays the message “
ERASE COMPLETED
”
and return to the
MAIN MENU
display.
2.
End of procedure.
Note
•
The instrument with a
null (‘0’) Identifier
(
IDENT
) cannot be deleted because it is
used as a template with factory default parameters.
•
If you press the
ENTER
key after having selected the null ID, the message “
NOT
POSSIBLE TO ERASE
” is displayed with no action and the main menu opens.
Procedure