If an error or warning no longer exists, this is indicated with the mode = Event disappears. In this case, the
corresponding entry in the list is set to EventQualifier = 0x00 and EventCode = 0x0000.
In this way, this parameter always indicates the current diagnostic status of the device.
The entire list can be reset via supply voltage OFF/ON or the system command Restore delivery status.
Index
Subindex
Name
Length
Type
Access
0x0025
0
Detailed Device Status
72 Bit
ArrayT
ro
Error_Warning_1
24 Bit
3 Bytes
ro
Error_Warning_2
24 Bit
3 Bytes
ro
Error_Warning_3
24 Bit
3 Bytes
ro
Byte
x+0
x+1
x+2
Bit
23
– 16
15
– 8
7
– 0
Data
2
7
– 2
0
2
15
– 2
8
2
7
– 2
0
EventQualifier
EventCode
Struktur, EventQualifier
Instance, Bit0... Bit2
- 0x04: application error
Source, Bit 3
- 0x00: Device
(remote)
- 0x01: Master
(local)
Type, Bit 4...5
- 0x02: Warning present
Mode, Bit 6...7
- 0x02: Event disappears