Operating Instructions
Page 47/60
Process Input Data - Status:
Status word contains status and error bits from the system.
Warning-/Error bits, b
it 8…15
0x80
Error
0x20
Warning
0x10
Report
Status bits, b
it 7…0
Process Input Data
– Chain Length:
The elongation is output as a signed two's complement value in 0.01% steps.
Process Input Data
– Chain Link Count:
The number of chain links passed through is output.
Process Input Data
– Max. Single Link Length:
The maximum lengthening within the chain is output as a signed two's complement value in 0.01% steps.
Process Input Data
– Max. Single Link Length Position:
Position of the chain link with the maximum elongation.
Process Input Data
– Chain Single Link Index count:
The number of runs of the single-link index marker is output.
Process Input Data
– Average Acceleration:
Average acceleration or shock to the CCM-S in mg.
Process Input Data
– Maximum Acceleration:
Maximum acceleration or shock on the CCM-S. Is reset to 0 after 10000 chain links and new measurement is started.
8.4 Parameterization
Parameter data are exchanged acyclically and only on request of the IO-Link master. The parameter data are
addressed via a so-called index and subindex.
This is a confirmed service. The IO-Link master specifies in its request the parameter Index, the access mode
Read/Slice and if necessary the data value. The IO-Link device executes the write or read access and responds to the
request with a response. In the event of an error (error code = 0x80), an error message provides information about the
cause of the error, see chapter 8.5.5.
The complete index is addressed via the subindex 0x00, the individual parameters are addressed via the subindices
0x01...0xFF if they exist.
8.4.1 Index 0x0010
– 0x0018: Identification parameter
The identification parameters contain device data that the IO-Link Master needs during start-up to identify the connected
device.
This device data can be read from the device via its index with subindex = 0x00 or written to the device.
The objects with index 0x0040 are optional objects added by the manufacturer.
Index
Object name
Value
(StringT)
Access
0x0010
Vendor Name
iwis
ro