Operating Instructions
Page 46/60
After receiving the answer, the data transmission rate COM 3 = 230.4 kBaud is set by the IO -Link master and the
communication is started. First, communication parameters are exchanged and, if necessary, parameters stored in
the system are transferred to the measuring system. Then the cyclic data exchange of the process data and the value
status is started.
8.3.4 Process Input Data
The following data is output via the process input data.
Index
Subindex
Name
Length
Type
Access
0x0028
0
ProcessDataInput
128 Bit
RecordT
ro
Status
16 Bit
UIntegerT16
ro
Chain Length
16 Bit
IntegerT16
ro
Chain Link Count
32 Bit
UIntegerT32
ro
Max. Single Link Length
16 Bit
IntegerT16
ro
Max. Single Link Length Position
16 Bit
UIntegerT16
ro
Chain Single Link Index count
32 Bit
UIntegerT32
ro
Structure
Byte
Bit
Process data
X+0
2
15
–2
8
Status
X+1
2
7
–2
0
Status
X+2
2
15
–2
8
Chain Length
X+3
2
7
–2
0
Chain Length
X+4
2
31
–2
24
Chain Link Count
X+5
2
23
–2
16
Chain Link Count
X+6
2
15
–2
8
Chain Link Count
X+7
2
7
–2
0
Chain Link Count
X+8
2
15
–2
8
Max. Single Link Length
X+9
2
7
–2
0
Max. Single Link Length
X+10
2
15
–2
8
Max. Single Link Length Position
X+11
2
7
–2
0
Max. Single Link Length Position
X+12
2
31
–2
24
Chain Single Link Index count
X+13
2
23
–2
16
Chain Single Link Index count
X+14
2
15
–2
8
Chain Single Link Index count
X+15
2
7
–2
0
Chain Single Link Index count
X+16
2
15
–2
8
Average Acceleration
X+17
2
7
–2
0
Average Acceleration
X+18
2
15
–2
8
Maximum Acceleration
X+19
2
7
–2
0
Maximum Acceleration