Operating Instructions
Page 49/60
8.4.2.2
Index 0x0047: Chain Logging Time
This parameter specifies the time at which the current elongation value is stored in the memory.
Time in 0,1h.
Index
Subindex
Name
Length
Type
Access
0x0047
0
Chain Logging Time
16 Bit
UIntegerT16
r/w
Byte
x+0
x+1
Bit
15
– 8
7
– 0
Data
2
15
– 2
8
2
7
– 2
0
Chain Logging Time (Binary)
Lower limit
1
Upper limit
1000
Default
20 (2,0h)
8.4.2.3
Index 0x004E: Standard Command
Execution of a command.
Index
Subindex
Name
Length
Type
Access
0x004E
0
Standard Command
16 Bit
UIntegerT16
r/w
Command
– New Chain:
The measured values are reset with the "New Chain" command. This command must be executed when using a new
chain or during commissioning.
Index
Subindex
Value
Length
Type
Access
0x004E
0
0x0001
16 Bit
UIntegerT16
r/w
8.4.3 Read Parameters
8.4.3.1
Index 0x0041: Distance
Display of the total distance in m.
Index
Subindex
Name
Length
Type
Access
0x0041
0
Distance
32 Bit
UIntegerT32
Ro
8.4.3.2
Index 0x0042: Running Time
Running time of the chain in 0,1h.
Index
Subindex
Name
Length
Type
Access
0x0042
0
Running Time
32 Bit
UIntegerT32
Ro