SERVICE MANUAL
SPIKA
23
p)
Sanitize all the interior surfaces of the freezing compartment (including the storage bin) applying liberally
sanitizer solution, using a cloth or sponge.
q)
Return shield to its position.
r)
Connect power and water supplies.
s)
Fill water reservoir with the sanitizer solution.
t)
Switch on machine in order to run water pump. Let solution stand for 20 minutes and switch off.
u)
Remove the auxiliary pipe to drain and purge out the sanitizer solution and residue. Replace it. Fill the
water reservoir with water and switch on the machine to allow water to circulate for 5 minutes and then
stop the machine. Repeat this operation two more times to rinse thoroughly.
v)
Remove the auxiliary hose to drain the water. Replace it and fill the tray with water to ensure the pump
works properly.
w)
Switch on compressor switch (I position)
x)
Return the back metal lid and the top panel to their position.
y)
Switch on machine and discard the first two harvests.
6.2.
Cleaning water distribution system for modular models (MS)
1)
Remove the front panel.
2)
Set Ice-wash switch to the OFF position (position 0) after ice falls from the evaporator at the end of a
harvest cycle, or set the ice-wash switch to the OFF position and allow the ice to melt off the evaporator.
CAUTION: Never use anything to force ice from the evaporator. Damage may result.
Front panel