SERVICE MANUAL
SPIKA
11
3.
PRIOR CHECKING AND START-UP
3.1.
Prior checking
Is the machine level?
Are the voltage and frequency as indicated on the plate?
Are the drains connected and do they work?
Is it connected to cold water?
** If the machine is air condensed, are the air circulation and the temperature of the premises right?
MAXIMUM
MINIMUM
AMBIENT TEMP.
43ºC
5ºC
WATER
35ºC
5ºC
Is the water pressure correct?
MINIMUM
1 Bar
MAXIMUM
6 Bar
NOTE: If the incoming water pressure is greater than 6 Bar, install a pressure reducer.
CAUTION: CHECK THAT THE VOLTAGE AND FREQUENCY OF THE MAINS ARE THE SAME AS THOSE INDICATED ON
THE NAME PLATE.
Air temp >30ºC
Water temp >20ºC
Air temp <30ºC
Water temp <20ºC
G1
G2
G3
G1
G2
G3
SPIKA NG 60
2X7
2X5
2X3
2X10
2X8
2X5
SPIKA NG 90
9
7
6
12
10
7
SPIKA NG 110
10
8
6
13
11
7
SPIKA NG 140
10
8
7
13
11
8
*indicating the number of white pins