SERVICE MANUAL
SPIKA
24
3)
Prepare a solution of an appropriate product for the cleaning of ice machines (lime). Do not use
hydrochloric acid. We recommend the use of any NSF approved scale removal product. In modular
machines the water bucket is filled automatically so we recommend to prepare a previous solution (for
example 1,89 liters(0,15 Gal)) according to the manufacturer’s instructions with the total quantity of
product needed for the water tray: 3 liters (0,8 gal) for MS 440 and 6 liters (1,6 gal) for MS 880 and 4,1
liters for MS 400/600 (0,9 gal).
To start a cleaning cycle, move the ice-wash switch to the WASH position (position II). The machine will
drain the reservoir and refill it. Pour the scale remover solution into the reserve.
Water level
sensor
Thickness
sensor
Ice-wash
switch
Shield
Water tray
MS 400/600 22
”
Curtain
Thickness
sensor
Ice-wash
switch
Water level
sensor
Water tray