SERVICE MANUAL
SPIKA
10
2.7.
Electrical connection
It is mandatory to ground the equipment. To avoid possible electric shock on individuals or damages to the
equipment, the machine should be grounded pursuant local and/or national regulations as the case may be.
The manufacturer shall be held harmless in case of damages arising due to the lack of the ground installation.
In case the supply cable is damaged, it should be replaced by a cable of special assembly to be furnished by the
manufacturer or after-sales service. Such replacement should be performed by qualified technical service only.
The modular units don’t have a cable with them. A qualified technical service must connect the power to the unit.
The machine should be places in such a way as to allow a minimum space between the back and the wall to allow
an easy access and without risks to the cable plug.
Safeguard the socket. It is convenient to install adequate switches and fuses.
Voltage is indicated in the nameplate and on the technical specifications section of this manual. Variation on
voltage above the 10% stated on the nameplate could result on damages or prevent the machine start-up.
MODELOS
VOLTAGE
FRECUENCIA
FASE
AMPS
TOTAL
FUSIBLE
(A)
(A)
SPIKA NG 60
220V / 50Hz / 1F
3
16
SPIKA NG 90
220V / 50Hz / 1F
3,5
16
SPIKA NG 110
220V / 50Hz / 1F
5
16
SPIKA NG 140
220V / 50Hz / 1F
5,5
16
SPIKA MS 220
220V / 50Hz / 1F
7
16
SPIKA MS 410
380V / 50Hz / 3F
4,2
16
SPIKA MS 410
208-230V / 60Hz / 1F
5,8
16
SPIKA MS 400/600
115V / 60Hz / 1F
14.5
20