SERVICE MANUAL
SPIKA
7
The air cooled SPIKA MS (modular) ice makers take the air through the back section and drive it off through the
two lateral louvers. In the case it is not possible to respect the minimum distances recommended (see the picture
in point 3.3) for these machines we recommend to install a water cooled unit.
The location must allow enough clearance for water, drain and electrical connections in the rear of the ice
machine. It is important that the water inlet piping does not pass near sources of heat so as not to lose ice
production.
2.2.
Levelling of the ice maker
Use a level on top of ice machine in order to ensure the equipment is perfectly leveled.
Screw the leveling legs onto the bottom of the ice machine as far as possible.
Move the machine into its final position.
Use a level on top of the ice machine. Adjust each leg as necessary to level the ice machine from front to back and
side to side.
ATTENTION: There is an optional 3 ½'' (=90mm) high casters kit that can be used in substitution of the standard
legs. These wheels are supplied with the corresponding installation instructions.
2.3.
Installation of modular equipments on top of bins
Modular ice makers should be installed on top of bins, following the instructions contained in this manual.
The resistance and stability of the container-machine/s assembly should be verified as well as the fastening
elements. Follow bin manufacturer instructions.