Bearings
The bearings (112, 112C, and 168C) should be inspected for contamination and damage. The condition
of the bearing will provide useful information on operating conditions in the bearing housing. Lubrication
condition and residue should be noted. Bearing damage should be investigated to determine the cause.
If cause is not normal wear, it should be corrected before the pump is returned to service.
NOTICE:
Do not re-use bearings
Oil Seals, O-Rings, Gaskets
Although the oil seals (332, 333), O-rings (351A, 351B, 496A, 496B, 496C) and gaskets (360R, 360X,)
may seem OK during inspection and examination, DO NOT RE-USE SEALS when rebuilding the pump.
Replace them while pump is disassembled.
6.3 Reassembly
60
Model AF (42"/1200mm/54"/60"/66") LM/LMR Bearings Installation, Operation, and Maintenance Manual