Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A)
Revised 8/98
10
5.1.3
Auto Open/Close in a Multi-Area System
When programming the system for split arming, there are several interrelated software options
that must be enabled in order for the system to function properly:
1.
SPLIT ARM, System Menu (Menu 4)
Must be enabled (select
YES
) for split arm systems.
2.
Area O/C Area Options (Menu 14)
You must select each area (1-8) that will use auto open/close.
When you program these options as described above, the selections you made for Default
mode (in System Options, Menu 4) and Auto O/C (Area Options, Menu 14) will operate as
programmed.
WARNING!
If you do not program Auto Open/Close areas as described here, the areas
will not follow the programmed time windows and will disarm if the system
enters Default mode.
5.2 Area Assignments
Each zone can be assigned to any one of the eight areas. Any number of zones can be assigned
to a particular area. This allows the installer to assign zones to areas after the system has been
wired, regardless of the type of hardware used in each zone. Chime zones only sound at touch-
pads in the same area. Entry and exit zones are activated by area also. There are separate entry/
exit timers for each area.
Each code can be assigned to any or all of the eight areas. The code can be used only at touch-
pads that are also assigned to the same area or areas.
Each touchpad can be assigned to one or more areas and more than one touchpad can be
assigned to each area. Each touchpad will display global system troubles and the status of any
areas to which it is assigned.
The Model 4180 Status Display Module can be programmed to activate speakers and bells for
alarm and trouble conditions that occur anywhere in the system or only for those that occur in
specific areas.
NOTE
The only items that report by area are openings and closings.
Section 6: Dumping Event Memory to Central Station
The 4724’s event memory can be transmitted to the central station to be saved as a permanent
record. Currently, this must be done using the Model 5540 Downloading Software.
The 4724's event memory can be uploaded using a procedure similar to the one used to upload
programmed options. The procedure is explained in Section 9.3 of this manual.