Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A)
Revised 8/98
17
DAYS#0:SMTWTFSH
Toggle between the digits 0-7, turning them on and off as necessary, to select the days the win-
dow will be active.
Examples:
1. If you want Time Window #0, which has been programmed to last from 7:00 to 8:30
AM, to be in effect on weekdays, select: -MTWTF- by toggling keys 1 through 5 on and
keys 0, 6 and 7 off.
2. If you want Time Window #3, which has been programmed to last from 8:00 to 9:00
AM, to be in effect on Sundays and holidays, then when you program
DAYS#3:SMTWTFSH, select S------H by toggling keys 0 and 7 on and keys 1 through 6
off.
NUMBER:#1
Select the next time window to program. Continue programming the options for up to 32 time
windows.
NOTE
The easiest way to disable a time window is to go to the Days option (Time Windows, Menu 0)
and deselect all days by pressing
CLR TEST
.
8.2 Access (Menu 1)
Access options and secret codes can be programmed by the user.
NOTE
There are no programming steps for Code 0 (installer's code) and Code 1 (main user's code)
functions because they are fixed. Code 0 can always activate all features, including the
Hexiprogramming mode. Code 1 can activate all control functions (arming, disarming,
bypassing, etc.) and can program all user-programmable options.
The secret codes for Code 0 and Code 1 are programmed in Test mode (see Section 7.6 of this
manual).
NUMBER:#2
Select the access code you want to program options for. Enter the identifying number (Code 2,
Code 3, etc.), not the secret code.
CODE#2:000000
Program the secret code for this access code. The code can be from four- to six-digits in length.
If you will be using the high security code, it must be entered as the secret code for Access
Code 255.
NOTE
Do not begin any codes with the same two digits that are used for the duress trigger. The
duress trigger is programmed under System (Menu 4).
ARS#2:12345678
Select the areas that this code may gain access by toggling the digits 1 through 8 on and off.
DOOR#2:YES
If this option is selected, this code will be able to gain access to doors (within the areas selected
in the previous option).
Press
0
for NO or
1
for YES.
NOTE
The 4724 is not UL Listed for door access control.