Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A)
Revised 8/98
16
Section 8: Programming Options Description
This section explains the options that can be programmed for the 4000 Series system when the
Model 4724 Control Expander is installed. The options are listed here are as they appear on the
touchpad display when the built-in programmer is used. The menu structure for the Model
5540 Downloading Software is slightly different. The selections shown below are the factory-
programmed default values.
This section shows ALL of the available options. However, some options will determine
whether or not another option is available.
For example: If you select
NO
for the auto test option, the daily test, test day and test time
options will not function.
NOTE
A. Before you begin programming, read through all options, locate your 4724 Programming
Record (P/N 466-1495), and write down all selections you plan to make for all options. The
procedure for using the built-in programmer is explained in Section 7 of this manual. Instruc-
tions for using the Model 5540 Downloading Software are in Section 9 of this manual.
B. After installing the 4724, you must reprogram all the options, even if the options were previ-
ously programmed. This is because the 4720 EEPROM (electrically erasable programmable
read-only memory), on which the options were originally programmed, is no longer used.
C. When the 4724 is installed, options can be programmed using the 4724's built-in program-
mer (accessed through any 4000 series touchpad) or the Model 5540 Downloading Software.
The Model 5520 Desk Top Programmer cannot be used with the Model 4724.
8.1 Time Windows (Menu 0)
The 4724 provides 32 available time windows (time periods), each specified by days of the
week and a starting and ending time. Each access code can be programmed to be used during
any combination of the 32 time windows (Access, Menu 1).
Opening and closing can be enabled by a programmed combination of the 32 time windows.
Each time window can also be enabled on holidays. Up to 16 calendar days can be designated
as holidays (Holidays, Menu 2).
For auto-arming, there is a programmable delay period that may extend the delay or cancel the
auto-arm. During the delay, the time remaining will be displayed at the touchpads along with
an audible warning. This delay is programmed in Timers (Menu 11).
These features replace the Normal/Special and Closed Days option previously used with the
4720. Time windows can be programmed by the user to provide optimum system flexibility.
NUMBER:#0
Select the time window to program.
START#0:00:00
Using military time, type in the beginning time for the window.
Examples: “15:00” is “3:00 PM” in military time.
END#0:00:00
Type in the ending time for the window.
Example:
A time window could be “18:59-00:00.”
NOTE
Time windows may cross midnight.