Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A)
Revised 8/98
30
24HR#1:NO
Select this option if the zone will be monitored for alarm conditions 24 hours a day (for exam-
ple, if it is a fire, emergency, or tamper zone).
EXIT#1:NO
Select this option if the zone will have an exit delay time or if it is an interior zone that is in the
exit corridor.
ENTRY1#1:NO
The system has the capability of having two separate entry delay times. Select this option if the
zone will be controlled by Entry Delay #1.
ENTRY2#1:NO
Select this option if the zone will be controlled by Entry Delay #2.
INTERIOR:NO
Interior zones can be bypassed as a group using the
INT
key.
NOTE
Select this option if the zone will be an interior zone.
BYPASS#1:NO
Select this option if you want to be able to bypass (shunt) the zone. If you do not select this
option for a particular zone, you will not be able to bypass that zone.
NOTE
Fire zones must NOT be bypassable.
CHIME#1:NO
This option enables the chime function for a particular zone. When the chime function is
enabled, the
CHM
key can be used to turn a door chime on and off when the system is dis-
armed.
AREA#1:1
Type in the number of the area to which you want to assign the zone. A zone can be assigned to
only one of eight areas.