Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A)
Revised 8/98
34
LN 1 ONLY#1:NO
Select this option if you wish to use Phone Line #1 ONLY with Phone #1. (You would typi-
cally do this only if using a direct line or using a WATTS line.)
LN 2 ONLY#1:NO
Select this option if you wish to use Phone Line #2 only with Phone #1.
DIRECT LN#1:NO
Select this option if you will be connecting the system directly to a Model 9000 Digital Alarm
Receiver without using the switched telephone network. You must also select a SIA (formerly
SEIA) format (requires a Model 9103 Line Card).
PHONE NUMBER#2
Enter Phone #2. Repeat the above steps for Account/Phone #2, #3, and #4.
NOTE
Account #4 will be sent to the downloading computer. Model 4150 Analog Reports will be sent
to Phone #4 using Account #4. Account #4 must be a SIA format when using the 4150.
8.9 Intercom (Menu 8)
Skip this menu if you are NOT using the Model 4140 Intercom/Telephone Controller.
TIMEOUT:30s
Enter (in seconds) the amount of time the intercom function will be active.
LONG DIST:YES
When this option is selected, the telephone function can be used for long distance calls.
PHONE TIME:NO
Select this option if you want the Phone feature to have a limited length for calls. The phone
time-out will be the same length selected for intercom time-out.
ONE WAY LI:NO
Select this option if you will be using the One-Way Listen-In feature, which allows central sta-
tion personal to listen to the installation without being heard. If you select
NO
, it will be possi-
ble for people at the installation to hear the central station personnel.
NOTE
Listen-in to duress or holdup is automatically one-way, regardless of how this option is pro-
grammed.
DTMF DIAL:YES
Select this option if you will be using Touch-Tone
®
dialing with the Telephone feature.
NEED D TONE:NO
Select this option if you wish the Telephone feature to wait for a dial tone before dialing.
MEM D ONLY:NO
If you select this option, only the two memory phone numbers can be dialed.