58
SBV System Series | Instruction manual v1.2 DEC 2021 | SAF-UM-SBVBus-en-v1.2 | © 2021 Inxpect SpA
6. Installation and use procedures
3. Click
Settings
>
Node ID Assignment
.
4. Proceed according to the type of assignment:
If the assignment is...
Then...
manual
1. Click
DISCOVER CONNECTED SENSORS
to display the connected
sensors.
2. To assign a Node ID, click
Assign
for the unassigned Node ID in the
Configured sensors
list.
3. To change a Node ID, click
Change
for the already assigned Node ID
in the
Configured sensors
list.
4. Select the SID of the sensor and confirm.
automatic
1. Click
DISCOVER CONNECTED SENSORS
to display the connected
sensors.
2. Click
ASSIGN NODE IDS
>
Automatic
.
semi-automatic
Click
ASSIGN NODE IDS
>
Semi-automatic
and follow the instructions
displayed.
6.2.10 Chain examples
Chain with control unit at the end of the chain and a sensor with bus terminator
Chain with control unit inside the chain and two sensors with bus terminator
6.2.11 Save and print the configuration
1. In the application, click
APPLY CHANGES
: the sensors will save the inclination set and the surrounding
environment. The application will transfer the configuration to the control unit, and once transfer is complete
it will generate a configuration report.
2. Click
to save and print the report.
3. Ask the authorized person for a signature.
6.2.12 Set the control unit Ethernet parameters
1. Ensure the control unit is turned on.
2. Press the Network parameter reset button and hold it down during steps 3 and 4.
3. Wait for five seconds.
Содержание SBV System Series
Страница 101: ......