Data type
Description
Communication
direction
Unsafe
TARGET DATA
l
Current distance and angle of the targets detected by each sensor.
For each detection field of each sensor, only the closest target to
the sensor is considered.
from the control
unit
Unsafe
DIAGNOSTIC DATA
ISC-B01 or ISC-02 control unit:
l
internal status with an extended description of the error condition
SBV-01 sensor:
l
internal status with an extended description of the error condition
from the control
unit
3.7 System configuration
3.7.1 System configuration
The control unit parameters have their own default values that can be modified via the Inxpect Safety application
(see "Parameters" on page 91).
When a new configuration is saved, the system generates the configuration report.
Note
: after a physical change of the system (e.g. new sensor installed), the system configuration must be updated
and a new configuration report must be generated, too.
3.7.2 Dynamic system configuration
SBV System Series allows a real-time adjustment of the most important system parameters, providing the means
to switch dynamically among different preset configurations. Via the Inxpect Safety application, once the first
system configuration (default configuration) has been set, it is possible to set alternative presets to allow a
dynamic real-time reconfiguration of the monitored area. The alternative presets are 3 through digital input and
31 through Fieldbus (if available).
These are the programmable parameters for each sensor:
l
detection field (from 1 to 4)
These are the programmable parameters for each detection field:
l
angular coverage (from 10° to 100° on the horizontal plane)
l
detection distance
l
safety working mode (
Both (default)
,
Always access detection
or
Always restart prevention
) (see
"Safety working modes and safety functions" on page 32)
l
status of the static object detection option (see "Restart prevention function: static object detection
option" on page 34)
l
restart timeout
All the remaining system parameters cannot be changed dynamically and are considered static.
3.7.3 Dynamic system configuration activation
The dynamic system configuration can be activated through the digital inputs or the safety Fieldbus (if available).
One activation method excludes the other and activation through digital inputs has priority over activation
through Fieldbus.
3. Get to know SBV System Series
SBV System Series | Instruction manual v1.2 DEC 2021| SAF-UM-SBVBus-en-v1.2 | © 2021 Inxpect SpA
25