74
SBV System Series | Instruction manual v1.2 DEC 2021 | SAF-UM-SBVBus-en-v1.2 | © 2021 Inxpect SpA
7. Maintenance and troubleshooting
Screen printing
Description
V12 sensors
Sensors power supply voltage
VUSB
USB port voltage
VREF
Inputs reference voltage (
VSNS Error
)
ADC
Analog-digital converter
7.4.4 Peripheral error (PERIPHERAL ERROR)
Error detected by diagnostics relative to the micro-controller, its internal peripherals or memories.
7.4.5 Configuration errors (FEE ERROR)
Indicates that the system must still be configured. This message can appear when the system is first turned on or
after reset to default values. It can also represent another error on the FEE (internal memory).
7.4.6 Output errors (OSSD ERROR)
Error
Meaning
OSSD 1 SHORT
CIRCUIT
Short-circuit error on MOS output 1
OSSD 2 SHORT
CIRCUIT
Short-circuit error on MOS output 2
OSSD 3 SHORT
CIRCUIT
Short-circuit error on MOS output 3
OSSD 4 SHORT
CIRCUIT
Short-circuit error on MOS output 4
OSSD 1 NO LOAD
No load detected on MOS output 1
OSSD 2 NO LOAD
No load detected on MOS output 2
OSSD 3 NO LOAD
No load detected on MOS output 3
OSSD 4 NO LOAD
No load detected on MOS output 4
OSSD 1-2 CROSS
CHECK
Short-circuit error between MOS output 1 and 2
OSSD 1-3 CROSS
CHECK
Short-circuit error between MOS output 1 and 3
OSSD 1-4 CROSS
CHECK
Short-circuit error between MOS output 1 and 4
OSSD 2-3 CROSS
CHECK
Short-circuit error between MOS output 2 and 3
OSSD 2-4 CROSS
CHECK
Short-circuit error between MOS output 2 and 4
OSSD 3-4 CROSS
CHECK
Short-circuit error between MOS output 3 and 4
7.4.7 Flash errors (FLASH ERROR)
A flash error represents an error on the external flash.
7.4.8 Dynamic configuration error (DYNAMIC CONFIGURATION ERROR)
A dynamic configuration error indicates an invalid dynamic configuration ID.
7.4.9 Internal communication error (INTERNAL COMMUNICATION ERROR)
Indicates that there is an internal communication error.
Содержание SBV System Series
Страница 101: ......