7. Maintenance and troubleshooting
Event
Type
Modbus connection
INFO
Session authentication
INFO
Validation
INFO
Log download
INFO
For further information about the events, see "INFO events" on the next page and " ERROR events (control unit)"
on page 73.
7.2.7 Verbosity level
There are six verbosity levels for the log. The verbosity can be set during the configuration of the system via the
Inxpect Safety application (
Settings
>
Activity History
>
Log verbosity level
).
Depending on the selected verbosity level, the events are logged in accordance to the following table:
Event
Level 0
(default)
Level 1
Level 2
Level 3
Level 4
Level 5
Diagnostic errors
x
x
x
x
x
x
System Boot
x
x
x
x
x
x
System configuration
x
x
x
x
x
x
Factory reset
x
x
x
x
x
x
Stop signal
x
x
x
x
x
x
Restart signal
x
x
x
x
x
x
Detection access
-
See "Verbosity level for detection access and exit events"
below
Detection exit
-
See "Verbosity level for detection access and exit events"
below
Dynamic configuration in
use
-
-
-
-
x
x
Muting status
-
-
-
-
-
x
7.2.8 Verbosity level for detection access and exit events
Depending on the selected verbosity level, the detection access and exit events are logged as follows:
l
LEVEL 0: no detection info is logged
l
LEVEL 1: the events are logged at control unit level and the additional information are the detection
distance (in mm) and the detection angle (°) in detection access.
Format:
CONTROL UNIT Detection access (distance mm/azimuth°)
CONTROL UNIT Detection exit
l
LEVEL 2: the events are logged in a single field at control unit level and the additional information are:
detection field, detection distance (in mm) and detection angle (°) in access, and detection field at exit.
Format:
CONTROL UNIT Detection access (field #n, distance mm/azimuth°)
CONTROL UNIT Detection exit (field #n)
l
LEVEL 3 / LEVEL 4 / LEVEL 5 The events are logged:
o
in a single field at control unit level and the additional information are: detection field, detection
distance (in mm) and detection angle (°) in access, and detection field at exit;
o
at sensor level and the additional information read by the sensor are: detection distance (in mm) and
detection angle (°) in access, and detection field at exit.
Format:
CONTROL UNIT #k
Detection access (field #n, distance mm/azimuth°)
SENSOR #k
Detection access (distance mm/azimuth°)