SECTION 5—SAFETY INSPECTION/TROUBLESHOOTING
R51™and R51LXP
30
Part No. 1106645
Information Gauge Display Diagnostics
Service Indicator Light Diagnostics
DISPLAY
DESCRIPTION
DEFINITION
COMMENTS
All LEDs are off.
Power is off.
All LEDs are on.
Power is on.
Fewer than three LEDs on
implies reduced battery
charge.
Left RED LED is flashing.
Battery charge is low.
The batteries should be
charged as soon as
possible.
Left to Right “chase”
alternating with steady
display.
Joystick is in
programming, inhibit
and/or charging mode.
The steady LEDs indicate
the current state of the
battery charge.
All LEDs are flashing slowly. Joystick has detected
Out-of-Neutral-at-Power-
Up mode.
Release the joystick back
to Neutral.
NUMBER
OF
FLASHES
ERROR CODE
DESCRIPTION
POSSIBLE SOLUTION
1
User Fault
Release joystick to neutral and try again.
2
Battery Fault
Charge the batteries. Refer to Charging Batteries on page 62.
Check that battery cables are connected properly. Refer to
Disconnecting/Connecting Battery Cables on page 57.
If necessary, replace batteries. Refer to Replacing Batteries on page 64.
3
Left Motor Fault
Contact Invacare/Dealer for service.
4
Right Motor Fault
Contact Invacare/Dealer for service.
5
Left Park Brake Fault
Contact Invacare/Dealer for service.
6
Right Park Brake Fault Contact Invacare/Dealer for service.
7
Remote Fault
Check to make sure joystick is connected properly.
Contact Invacare/Dealer for service.
8
Controller Fault
Contact Invacare/Dealer for service.
9
Communications Fault Contact Invacare/Dealer for service.
10
General Fault
Contact Invacare/Dealer for service.
11
Incompatible or
incorrect Remote
Wrong type of remote connected. Contact Invacare/Dealer for service.